Bluelab Conductivity Pen
Growing-condition measurement or control
Sensors and controllers measure or act on devices through supported interfaces.
Current per recorded source Version unknown

Key specifications
- Sensors and measured quantities
- Conductivity and temperature
- Physical interfaces
- Handheld display
- Calibration
- Factory-calibrated conductivity
- Brand
- Bluelab
- Model
- Conductivity Pen
- Generation / revision
- Unknown
- Regional version
- Unknown; confirm exact plug, voltage and SKU
- Classification
- Growing Automation & Controls
- Technical route
- Growing-condition measurement or control (editorial classification)
- Product status
- current — Published official catalog record; at least one variant available=true. This is not a stock or delivery guarantee.
- Verified
- 2026-11-25
Technical parameters and evidence
Unknown means unverified. The source column distinguishes manufacturer declarations from other evidence. Conflicting values remain in the source record.
| Parameter | Value | Evidence and date |
|---|---|---|
| Physical interfaces | Handheld display | Bluelab Conductivity Pen manufacturer declaration · 2026-11-25 catalog description |
| Communications protocol | Unknown | No verified value |
| Sensors and measured quantities | Conductivity and temperature | Bluelab Conductivity Pen manufacturer declaration · 2026-11-25 Product introduction and own features; cross-sell mentions excluded |
| Controlled equipment | Unknown | No verified value |
| Calibration | Factory-calibrated conductivity | Bluelab Conductivity Pen manufacturer declaration · 2026-11-25 catalog description |
| Compatibility conditions | Unknown | No verified value |
| Power supply | Unknown | No verified value |
| Device ports | Unknown | No verified value |
Configuration and compatibility
No additional configuration verified. Confirm exact hardware, power supply and regional SKU against its manual.
Use this pen for concentration checks between samples
This handheld measures conductivity and temperature and starts from a factory-calibrated conductivity specification. Document the sample point, units and temperature so refill checks use a comparable basis. Bluelab's troubleshooting guide recommends cleaning and checking the sensor in its conductivity standard. A persistently inaccurate check after cleaning can justify the manufacturer's conductivity calibration procedure.
Compare the Combo Meter when you also need pH at every stop. The Conductivity Pen can be the simpler choice if another instrument already handles pH. Its reading is an aggregate electrical property, so the result does not by itself establish the amount of a particular nutrient. A dirty sensor can make a change look like a reservoir problem and should be ruled out before drawing that conclusion.
Rule out a dirty electrode before changing the reservoir
If this pen reads lower than expected, check it after cleaning in the manufacturer’s conductivity standard. A low result from a contaminated electrode can look like a change in the solution. This fault check is specific to the EC pen and is separate from the two-point pH calibration used on the Combo Meter’s pH channel.
Additional manufacturer evidence
- Bluelab Conductivity Pen troubleshooting and calibration — Manufacturer Support. Calibration and cleaning questions explain testing after cleaning, starting factory calibration and the circumstances for user calibration. .
Known limits
- Manufacturer declarations; no independent testing by GROWVELIA.
- Unknown fields are unverified, not zero.
- Confirm the exact regional SKU and hardware revision with its manual before purchase or connection.
- Meter-only devices measure conditions and do not switch growing equipment.
- Follow Bluelab’s Conductivity Pen cleaning and verification procedure.
Official sources
- Bluelab Conductivity Pen — manufacturer product data; verified 2026-11-25
Sources document the exact model and test conditions where available.
Conflicts and missing information
No conflict recorded in the reviewed evidence; this is not proof that all sources agree.
Missing technical fields: Communications protocol, Controlled equipment, Compatibility conditions, Power supply, Device ports. Missing identity fields: version, region.
How to read evidence coverage
Coverage describes the record, independent of product performance. Not Applicable fields are excluded from the denominator.
- Documented
- A source records the value.
- Not Provided
- An applicable field has no value in the record.
- Not Applicable
- The field is outside the applicable scope.
- Conflicting Data
- Sources disagree and the value is withheld from dependent decisions.
- Unknown
- The value, revision or market status could not be established.