Mars Hydro TS-600

panel led

Panels, bars and spotlights deliver light over a specified area and mounting distance.

Unknown MARS-TS-02 202211 documented revision

Linear grow lights over indoor plant shelves.
Equipment category illustration

Key specifications

Rated fixture power
100 W
Coverage with stated conditions
2 × 2 ft
Dimming
Not dimmable
Power supply
NA 110–130 V; EU 220–240 V

View the complete specification and evidence table

Brand
Mars Hydro
Model
TS-600
Generation / revision
MARS-TS-02 202211 documented revision
Regional version
Unknown; confirm exact plug, voltage and SKU
Classification
Plant Lighting Systems
Technical route
panel led (editorial classification)
Product status
unknown — Current sale status not established by this technical document.
Verified
2026-11-25

Technical parameters and evidence

Unknown means unverified. The source column distinguishes manufacturer declarations from other evidence. Conflicting values remain in the source record.

Mars Hydro TS-600 source-scoped parameters
ParameterValueEvidence and date
Rated fixture power100 WMars Hydro TS series manual MARS-TS-02 202211
manufacturer declaration · 2026-11-25
Manual table Input Power ±5%
Photosynthetic photon fluxUnknownNo verified value
PPFD with measurement conditionsUnknownNo verified value
Photon efficacyUnknownNo verified value
SpectrumUnknownNo verified value
Measurement distanceUnknownNo verified value
Coverage with stated conditions2 × 2 ftMars Hydro TS series manual MARS-TS-02 202211
manufacturer declaration · 2026-11-25
Manual table Footprint; distance not specified
DimmingNot dimmableMars Hydro TS series manual MARS-TS-02 202211
manufacturer declaration · 2026-11-25
Technical specifications
Power supplyNA 110–130 V; EU 220–240 VMars Hydro TS series manual MARS-TS-02 202211
manufacturer declaration · 2026-11-25
Technical specifications
External dimensions35.6 × 31 × 3.6 cmMars Hydro TS series manual MARS-TS-02 202211
manufacturer declaration · 2026-11-25
Technical specifications

Configuration and compatibility

No additional configuration verified. Confirm exact hardware, power supply and regional SKU against its manual.

A compact fixed-output panel for a stable height

The TS 600 manual records 100 W, a compact housing and no dimming. That is useful when the receiving plane and mounting position are stable. If canopy height changes often, investigate the manufacturer's placement instructions and assess whether the room allows enough adjustment by moving the fixture.

The same manual gives different regional supply ranges for the 600 than the broader nominal range on the TS 1000 entry. Match the exact unit to the intended supply. Compare the 1000 if dimming at a fixed height would solve a recurring control problem.

Allow a usable height adjustment path for the fixed-output panel

Check the space still available above the fixture when the crop is tallest. The non-dimmable TS 600 cannot use the adjustment workflow documented for TS 1000. Confirm the actual regional voltage before fixture selection, then verify exposure at the lowest practical operating height.

Known limits

  • Manufacturer documentation; no GROWVELIA hands-on test.
  • Do not infer missing specifications or compatibility.
  • Capacity, fixture output and coverage are not measured harvest results.
  • Historical documentation revision; current hardware and sale status are unknown. Do not transfer these specifications to another generation.

Official sources

Sources document the exact model and test conditions where available.

Compare compatible product specifications

Conflicts and missing information

No conflict recorded in the reviewed evidence; this is not proof that all sources agree.

Missing technical fields: Photosynthetic photon flux, PPFD with measurement conditions, Photon efficacy, Spectrum, Measurement distance. Missing identity fields: region.

How to read evidence coverage

Coverage describes the record, independent of product performance. Not Applicable fields are excluded from the denominator.

Documented
A source records the value.
Not Provided
An applicable field has no value in the record.
Not Applicable
The field is outside the applicable scope.
Conflicting Data
Sources disagree and the value is withheld from dependent decisions.
Unknown
The value, revision or market status could not be established.

Back to Products