Comparing electricity across schedules and tariffs
Compare the same service before comparing the bill
Decide whether both alternatives serve the same device boundary. Comparing an entire cabinet, including its pump and fans, against the light bar in another setup answers an uneven question. List components for both alternatives and decide where differences in coverage, use time or service should stay visible. Fixture efficiency on paper does not establish equal delivered light or equal schedules. Estimate the electricity side of the plan separately from the growing service it provides.
Give each complete alternative its own device name. For a scheduling comparison, two different device names can represent the same physical fixture under different plans. Within a device, give a repeated physical load the same component name across tariff rows. The validator sums those rows’ durations together. Different physical loads can run at the same time, so their combined operating hours may exceed 24 without violating the rule for any individual load.
Build an energy and tariff record
Enter average input watts appropriate to the segment. A plug-in energy meter’s integrated energy over a representative period can help establish an average for a cycling load. A nameplate may provide useful evidence about rated input without establishing the actual average under a particular setting. If no observed or documented value fits the design, use an explicitly labeled range of assumptions rather than treating an upper bound as a measured load.
A time-of-use rate is a charge per kWh for a defined period. Split a component at the boundaries of the bill’s relevant periods, and document the actual times outside the tool. The form has a duration and tariff rather than clock start and stop entries. Its 24-hour check guards against excess duration for a component, but cannot detect a clock overlap when the declared durations still fit inside a day. Keep the correct currency consistent across rows and consider taxes, standing charges and tier rules separately according to your own tariff.
Calculate one day and scale the repeated plan
Watts divided by 1,000 gives kilowatts. Multiplying by segment hours gives kWh, and multiplying by that segment’s rate gives a cost. Segment costs and energy are summed per device. The annual and multi-year values repeat the input plan for the entered operating days and years. The cost spread is the difference between the highest and lowest horizon totals among alternatives. It does not add the bills or rank the value of the equipment.
A seasonal operation with many non-operating days still may have an off-season load. Treat an active schedule and standby schedule as separate sub-calculations when their numbers of days differ. Likewise, weekend or seasonal tariff regimes can use separate runs and a documented sum. Avoid relabeling a calendar day as active just to include a standby rate, which duplicates the operating load.
Interrogate a surprising result
If two plans consume the same energy but have different total cost, check which charges changed with the schedule. If a higher device wattage still yields lower cost, compare actual run time and the interval rates. When one row has runtime zero, distinguish a deliberate off interval from an unknown operating duration. Zero measured energy during a stated interval is materially different from a missing measurement.
The estimates omit capital cost and consumables. They also assume a repeated schedule with unchanging rates unless you run distinct assumptions separately. Export the input table and record whether each wattage came from a meter, a manufacturer declaration or a planning assumption. A small ranking difference may reverse under a different runtime or electric rate. Keep that sensitivity visible instead of claiming a future bill is settled.
Worked examples
Scenario values are illustrative. Model examples use the identified product records and their documented limits.
Same energy, shifted peak hours
Illustrative Scenario
An illustrative 100 W light operates eight hours per day. One plan has four hours at 0.30 and four at 0.10. The other keeps all eight hours at 0.10.
| Input | Value |
|---|---|
| Operating days/year | 365 |
| Years | 1 |
| Row | Device | Component | Average W | Segment hours/day | Currency/kWh |
|---|---|---|---|---|---|
| 1 | Split | Light | 100 | 4 | 0.3 |
| 2 | Off-peak | Light | 100 | 8 | 0.1 |
| 3 | Split | Light | 100 | 4 | 0.1 |
How the result follows
Each day is 0.8 kWh in either plan. The daily costs are 0.16 and 0.08, giving annual costs 58.40 and 29.20.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Devices | 2 |
| Lifetime cost difference (input currency) | 29.2 |
| Rows 1 · Daily Kwh | 0.8 |
| Rows 2 · Daily Kwh | 0.8 |
What to do with the result
Savings come from the tariff timing, with no modeled energy saving.
Scope of this example
Real time-of-use boundaries were not supplied.
Small pump counted on both alternatives
Illustrative Scenario
An illustrative system A uses a 60 W light for 12 h and a 10 W pump for 24 h; B uses a 40 W light for 16 h and a 5 W pump for 24 h. All cost 0.20/kWh for 300 days annually.
| Input | Value |
|---|---|
| Operating days/year | 300 |
| Years | 3 |
| Row | Device | Component | Average W | Segment hours/day | Currency/kWh |
|---|---|---|---|---|---|
| 1 | A | Light | 60 | 12 | 0.2 |
| 2 | A | Pump | 10 | 24 | 0.2 |
| 3 | B | Light | 40 | 16 | 0.2 |
| 4 | B | Pump | 5 | 24 | 0.2 |
How the result follows
A has 0.96 kWh/day and B has 0.76. Over 900 operating days the cost totals are 172.80 and 136.80.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Devices | 2 |
| Lifetime cost difference (input currency) | 36 |
| Rows 1 · Lifetime Cost | 172.8 |
| Rows 2 · Lifetime Cost | 136.8 |
What to do with the result
The three-year spread is 36 in the entered currency.
Scope of this example
Equal growing service is a separate question.
Seasonal schedule
Illustrative Scenario
An illustrative 150-day plan compares 30 W for ten hours with 50 W for eight hours at 0.25/kWh over two years.
| Input | Value |
|---|---|
| Operating days/year | 150 |
| Years | 2 |
| Row | Device | Component | Average W | Segment hours/day | Currency/kWh |
|---|---|---|---|---|---|
| 1 | A | Lamp | 30 | 10 | 0.25 |
| 2 | B | Lamp | 50 | 8 | 0.25 |
How the result follows
At 0.30 and 0.40 kWh/day, the two-year cost totals are 22.50 and 30.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Devices | 2 |
| Lifetime cost difference (input currency) | 7.5 |
| Rows 1 · Annual Kwh | 45 |
| Rows 2 · Annual Kwh | 60 |
What to do with the result
The spread is 7.50 for the active period assumptions.
Scope of this example
Off-season loads would need a separate calendar entry.
Three cabinet configurations
Illustrative Scenario
An illustrative 200-day system comparison uses 100 W, 70 W or 80 W light loads each running ten hours at 0.40.
| Input | Value |
|---|---|
| Operating days/year | 200 |
| Years | 1 |
| Row | Device | Component | Average W | Segment hours/day | Currency/kWh |
|---|---|---|---|---|---|
| 1 | A | Light | 100 | 10 | 0.4 |
| 2 | B | Light | 70 | 10 | 0.4 |
| 3 | C | Light | 80 | 10 | 0.4 |
How the result follows
The annual costs are 80, 56 and 64. The highest minus lowest gives 24.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Devices | 3 |
| Lifetime cost difference (input currency) | 24 |
| Rows 3 · Annual Cost | 64 |
What to do with the result
A single spread summarizes the bounds; the middle option remains visible in the table.
Scope of this example
The three options could deliver different light to plants.
Same component across a full day
Illustrative Scenario
A hypothetical 25 W circulating pump runs continuously in A, twelve hours at 0.15 and twelve at 0.25. B uses a 15 W pump for 24 hours at 0.20.
| Input | Value |
|---|---|
| Operating days/year | 365 |
| Years | 1 |
| Row | Device | Component | Average W | Segment hours/day | Currency/kWh |
|---|---|---|---|---|---|
| 1 | A | Pump | 25 | 12 | 0.15 |
| 2 | A | Pump | 25 | 12 | 0.25 |
| 3 | B | Pump | 15 | 24 | 0.2 |
How the result follows
A's 0.60 kWh costs 0.12/day. B's 0.36 kWh costs 0.072/day. The annual difference is 17.52.
What the tool returned
Calculated
| Result field | Observed value |
|---|---|
| Lifetime cost difference (input currency) | 17.52 |
| Rows 1 · Daily Cost | 0.12 |
| Rows 2 · Daily Cost | 0.072 |
What to do with the result
The split component duration is exactly 24 hours; neither row represents a second pump.
Scope of this example
Both pump draws are illustrative averages rather than equipment measurements.
Read next
Related original case studies
- Moving Light Hours Can Lower Cost Without Saving Energy
Shows a schedule shift that lowers spending while using the same energy.
- Seasonal Use Needs an Off-Season Ledger Too
Separates active operating days from off-season consumption.
- Higher Photon Efficacy Does Not Guarantee a Smaller Electricity Bill
Explains how different operating hours can erase an apparent power saving.
Technical guides
- Understanding Growing Cabinet Energy Consumption
Builds a comparison from component draw and operating regimes.
- The True Cost of Owning a Countertop Indoor Garden
Places the electricity result within a broader ownership budget.
Sources and equipment records
References for the method
- Virginia Tech: Estimating appliance energy use
Watts × hours / 1000 = kWh