Grow Light Performance Comparator

Compare lighting specifications with explicit evidence limits and derive a declared photon-per-watt ratio only when inputs are usable.

Growers checking exact fixture revisions and evidence before comparing optical performance or electrical load.

Inputs
Two to four fixtures from the product database
Results
Sourced light and power fields, comparable conditions, and declared PPF/watt ratios

Compare declared photon and electrical parameters with measurement and conflict safeguards.

Calculation method

Reuse lighting-specific comparisons. Declared PPF / declared W is a derived ratio when both source-scoped values are known and unconflicted.

Scope

The derived ratio is not an independent PPE test. PPFD comparisons require equal known measurement conditions. Quarantined official conflicts cannot be selected as truth.

Back to Tools

Comparing documented fixture performance

Select fixtures by exact identity

Start with the labels from the fixtures or the precise variants in the specification you are evaluating. Select two to four distinct records. Product model suffixes, regional versions and revisions can change the evidence available for an apparently familiar name. A rated electrical input can be documented even when the same record has no usable photon claim. The page shows fields independently so one well-documented parameter does not lend certainty to another.

The inputs are database products. If you want to compare a map you took yourself, use the coverage tool. Manual PPFD readings do not replace catalog records here. The evidence sidebar can provide context for a product but does not add a selected fixture to the comparison.

Read the three photon and electrical quantities separately

Input watts describe an electrical rate. PPF describes total emitted photosynthetic photon flux in µmol/s. Dividing declared PPF by declared input watts gives µmol/J, a numerical efficacy ratio whose scope stays with those declarations. The result does not create an independent test or replace documented PPE. Confirm that both values refer to the same operating condition if you need to use the ratio in a decision. For example, an output claimed at full power should not be paired with a low dimmer input reading to estimate the full-power efficacy.

PPFD describes photons arriving per area per second. A high fixture PPF does not put the same amount of light everywhere and cannot establish an adequate PPFD at every shelf position. Even a higher catalog efficacy remains a fixture-level statement. A system may need two fixtures, mount closer or run at a different setting to deliver the target coverage. When the task is to light a specific area, include the distance, map geometry, sampling and power mode in the comparison before drawing a conclusion.

Follow the evidence status before reading any apparent winner

A row may show a known claim for each product without making the claims directly comparable. Source scope, test geometry, distance or terminology may differ. A comparative claim about PPFD needs matching documented measurement conditions. Leave a metric undecided if its measurement basis cannot be established. In particular, never treat a model missing a value as supplying zero photons or consuming zero power.

Open the conflict evidence when a source field disagrees with another declaration. Quarantined values remain visible for provenance where available; the comparison does not use those values in the declared ratio. A published efficacy in one source does not give you permission to reverse-calculate a missing PPF when the inputs are absent or disputed. Check a rate against the source units before copying a ratio to a spreadsheet, and retain exposure and operating context alongside that export.

Match the comparison to a purchase or installation decision

If the device shares a circuit with a cabinet and pump, credible input power can answer a budget question before you have optical evidence. If the requirement is an edge PPFD across a particular rack, reserve the decision until you have a useful map. Where lamps serve different purposes or optics, compare the evidence first and then map the application. A small difference in PPF/W is often less actionable than an unresolved installation issue, such as whether one fixture can occupy the necessary position.

Use an independent, scoped measurement when the available source figures cannot support the desired comparison. Record fixture identity, dimmer setting, distance and the measuring method. That evidence can be interpreted alongside the catalog. This page does not accept new product specifications or confirm optical performance from an unreviewed map.

Worked examples

Scenario values are illustrative. Model examples use the identified product records and their documented limits.

Two older revisions with quarantined optical claims

Illustrative Scenario

The illustrative decision is between the documented Spider Farmer SF1000 and SF2000 records.

Entered values
InputValue
Select two to four real product recordsSpider Farmer SF1000 (2026), Spider Farmer SF2000 (2026)

How the result follows

The catalog preserves model power but no usable PPF for either ratio. Both derived entries must therefore be null.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Products2
Derived Ratios0
Declared Ratios 1 · Derived Declared PpeUnknown

What to do with the result

Power can inform one part of an electrical brief; efficacy and coverage remain unresolved.

Scope of this example

Do not pick a side from the quarantined claims.

Two SANSI fixtures with usable source values

Illustrative Scenario

Compare the recorded PAR20 10W and BR30 24W for a hypothetical decision.

Entered values
InputValue
Select two to four real product recordsSANSI PAR20 10W, SANSI BR30 24W

How the result follows

From the declarations, 16.8 ÷ 10 = 1.68 and 36.2 ÷ 24 ≈ 1.5083 µmol/J.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Products2
Derived Ratios2
Declared Ratios 1 · Derived Declared Ppe1.68
Declared Ratios 2 · Derived Declared Ppe1.508333333

What to do with the result

Both ratios are available for auditing. The larger declared output can coexist with a lower declared ratio.

Scope of this example

The ratio cannot establish the PPFD distribution at your mounting height.

One available ratio in a mixed comparison

Illustrative Scenario

Compare Soltech Highland with Barrina TR40A3 in an illustrative shelf selection.

Entered values
InputValue
Select two to four real product recordsBarrina TR40A adjustable, Soltech Highland

How the result follows

The Highland record provides 40 µmol/s and 30 W. The Barrina record does not provide a usable PPF. Only one ratio, around 1.3333, can be derived.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Products2
Derived Ratios1
Declared Ratios 2 · Derived Declared Ppe1.333333333
Declared Ratios 1 · Derived Declared PpeUnknown

What to do with the result

The absence of a second ratio prevents a two-model efficacy conclusion.

Scope of this example

Track mount geometry and seek measurements before selecting a shelf solution.

Three sourced cases with one missing input set

Illustrative Scenario

Use ViparSpectra P1000, SANSI BR30 36W and Soltech Vita to explore mixed evidence coverage.

Entered values
InputValue
Select two to four real product recordsViparSpectra P1000, SANSI BR30 36W, Soltech Vita

How the result follows

No source-scoped PPF is usable for P1000 here. The other two figures are 65.6 ÷ 36 and 25.95 ÷ 20.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Products3
Derived Ratios2
Declared Ratios 2 · Derived Declared Ppe1.822222222
Declared Ratios 3 · Derived Declared Ppe1.2975

What to do with the result

Two ratios are available for separate evidence checks, not a three-model ranking.

Scope of this example

The applications and optics can differ despite sharing the same computed unit.

Four fixtures with asymmetric provenance

Illustrative Scenario

For a hypothetical comparison use SF1000D, SANSI A21 15W, Soltech Grove and Barrina T1X3.

Entered values
InputValue
Select two to four real product recordsSANSI A21 15W (C21GL-DE26-15W documented), Barrina T1X3, Spider Farmer SF1000D (2026), Soltech Grove

How the result follows

The catalog supports the A21 division 27.2 ÷ 15 and Grove division 17 ÷ 11. SF1000D and T1X3 cannot supply a usable ratio.

What the tool returned

Calculated

Verified output
Result fieldObserved value
Products4
Derived Ratios2
Declared Ratios 1 · Derived Declared Ppe1.813333333
Declared Ratios 4 · Derived Declared Ppe1.545454545

What to do with the result

The A21's electrical compatibility evidence is separate from its declared photon ratio.

Scope of this example

Keep product restrictions visible even where a different field can be calculated.

Read next

Sources and equipment records