Reservoir Capacity Planner

Estimate drawdown, the time to the operating minimum, and the amount left after reserving days of measured demand.

Growers preparing refill intervals or comparing several states of one reservoir.

Inputs
Effective filled volume, operating minimum, daily use and reserve days
Results
Usable water, estimated days and reserve margin

Estimate depletion and reserve from effective filled volume and measured daily water demand.

Calculation method

Consumable volume = filled volume − operating minimum. Interval = consumable volume / measured daily loss. Reserve = days × measured loss.

Scope

Zero loss means no finite depletion interval can be inferred. This does not estimate water use from plant count or predict changes in demand.

Back to Tools

Planning a refill window from observed use

Plan a refill from the running inventory

A reservoir may look full while offering only a small amount of liquid that the grower can use. Some water must stay in the system for the chosen operation, and the number on a listing may describe an outside container volume or a brimful capacity. Start from an effective fill observed under the operating condition you care about. Measure the operating minimum from the same boundary and in the same state.

Measure loss before choosing the interval

Record the starting amount, additions, withdrawals and ending amount across a known period. If liquid moved to another vessel or remained in the lines, account for that change consistently. Separate deliberate drainage from loss if your result is intended to describe normal depletion. A leak is worth investigating rather than treating as a stable feature of the reservoir.

The planner first subtracts the minimum from the fill. It divides the result by your daily loss to estimate time to that minimum. It then converts reserve days into liters and subtracts those liters from the usable inventory. A positive volume after reserve is available for routine use. A negative value signals a shortfall in the plan.

Turn a result into an inspection plan

The gross interval reaches the operating boundary and is a poor appointment time if you want a reserve. Use the volume available after reserve to reason about a shorter refill routine, and inspect independently when use can change with conditions. Consider rerunning for two observed or defensible rates to see how much the routine depends on an uncertain estimate.

When a product figure is usable

An optional binding requires a documented effective filled-volume definition; a number labeled tank capacity can fail this check even if it is known. Verify the measurement basis before treating it as the filled quantity. A zero-loss observation will not give a finite interval, and multiple unconnected tanks need separate budgets. The planner does not predict nutrient concentration or the behavior of a top-up device.

Worked examples

Scenario values are illustrative. Model examples use the identified product records and their documented limits.

A weekly refill plan

Illustrative Scenario

A running reservoir starts with 5 L, needs 1 L to operate, and loses 0.5 L per day.

Entered values
InputValue
Effective filled volume (L)5
Minimum operating volume (L)1
Measured total daily water loss (L/day)0.5
Desired reserve duration (days)2

How the result follows

5 − 1 = 4 L usable. Gross interval: 4 ÷ 0.5 = 8 days. Two reserve days require 1 L, leaving 3 L for routine use.

What the tool returned

Calculated

Constant measured demand assumed; inspect water level independently.

Verified output
Result fieldObserved value
Usable volume (L)4
Estimated Days8
Reserve (L)1
Remaining After Reserve Liters3

What to do with the result

Refilling after seven days would consume part of the protected reserve.

Scope of this example

Treat loss as a representative observation, not a guaranteed daily demand.

Use the running level

Illustrative Scenario

An illustrative tank holds 10 L stopped and 8.4 L running. The running minimum is 2.4 L.

Entered values
InputValue
Effective filled volume (L)8.4
Minimum operating volume (L)2.4
Measured total daily water loss (L/day)1.5
Desired reserve duration (days)1

How the result follows

Subtract matching running values to get 6 L. At 1.5 L per day the gross interval is 4 days; after reserving 1.5 L, 4.5 L remains for routine drawdown.

What the tool returned

Calculated

Constant measured demand assumed; inspect water level independently.

Verified output
Result fieldObserved value
Usable volume (L)6
Estimated Days4
Remaining After Reserve Liters4.5

What to do with the result

Pair operating-state measurements consistently.

Scope of this example

Do not infer how much water occupies individual pipes from these entries.

Reserve is larger than drawdown

Illustrative Scenario

A 5 L working fill leaves 2 L above a 3 L minimum. The observed loss is 1 L/day and three days must be protected.

Entered values
InputValue
Effective filled volume (L)5
Minimum operating volume (L)3
Measured total daily water loss (L/day)1
Desired reserve duration (days)3

How the result follows

The 2 L usable inventory reaches the minimum after 2 days. A 3 L reserve leaves a negative 1 L margin.

What the tool returned

Calculated

Constant measured demand assumed; inspect water level independently.

Verified output
Result fieldObserved value
Estimated Days2
Reserve (L)3
Remaining After Reserve Liters-1

What to do with the result

The entered inventory cannot support this reserve plan.

Scope of this example

Increasing fill requires a separate safe-capacity check.

No change during one observation

Illustrative Scenario

In a 12 L running reservoir with a 3 L minimum, the observation resolves no net loss.

Entered values
InputValue
Effective filled volume (L)12
Minimum operating volume (L)3
Measured total daily water loss (L/day)0
Desired reserve duration (days)4

How the result follows

9 L is above the minimum. Division by zero does not supply a finite duration. Under the supplied rate, the calculated reserve volume is 0 L.

What the tool returned

No depletion in supplied observation

No finite refill interval can be inferred from a zero-use observation.

Verified output
Result fieldObserved value
Usable volume (L)9
Estimated DaysUnknown
Reserve (L)0

What to do with the result

Inspect the observation window and resolution before treating this as a schedule.

Scope of this example

A recorded zero is specific to the observation and does not prove zero future loss.

Account for an intervening top-up

Illustrative Scenario

The system starts the day at 9 L, receives 1.5 L and ends at 8.5 L. Use 9 L as the planned start.

Entered values
InputValue
Effective filled volume (L)9
Minimum operating volume (L)3
Measured total daily water loss (L/day)2
Desired reserve duration (days)1

How the result follows

Daily loss is 9 + 1.5 − 8.5 = 2 L. 6 L of usable liquid gives 3 gross days and leaves 4 L after reserve.

What the tool returned

Calculated

Constant measured demand assumed; inspect water level independently.

Verified output
Result fieldObserved value
Usable volume (L)6
Estimated Days3
Remaining After Reserve Liters4

What to do with the result

The 0.5 L visible level change would have understated the water lost.

Scope of this example

This balance assumes no unrecorded drains or transfers.

Read next

Sources and equipment records